  • Insulation & Multifunction Tester (LCD Display)

    1153 AI - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1154 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1152 MF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1155 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

  • Guardian Hipot Tester AC/DC/IR/SCAN

    19050 - Chroma Systems Solutions, Inc.

    The Chroma Guardian 19050 series of Hipot Testers are comprised of three models. The Guardian 19052 is equipped for AC/DC/IR Hipot testing and insulation resistance (IR) measurements. The Guardian 19053 combines both AC and DC Hipot tests and IR measurements with 8HV scan channel capabilities. The Guardian 19054 combines both AC and DC Hipot tests and IR measurements with 4HV scan channel capabilities.

  • Test Sets For Diagnostic Testing

    NEO TELE-TRONIX PVT. LTD

    Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.

  • Testing Services

    ION Corporation

    *Programmable Multipoint Tester*Over 8,000 programmable test points (DWV, Capacitance, Insulation Res., 2/4-Wire Resistance, etc.)*1500VDC / 1000 VAC Dielectric Withstanding Voltage (DWV)/ Hi-Pot (Programmable Dwell times)*Full Electronics laboratory complete with state of the art testing equipment*Custom Unit Testing (Designing of Specialized Test fixtures)*EMI Testing*Temperature and Humidity Testing*Shock Testing*Vibration Testing*Sand and Dust / Altitude Testing*Military Qualification Tests Performed

  • Electric Insulation Oil Automatic Measurement System

    DAC-5016 - Soken Electric Co. Ltd

    DAC-5016 is an automatic test system of insulation oils according to JIS C-2101.The system automatically enables changing over samples (liquid cells) up to max 8 pieces and testing the dielectric loss tangents and the volume resistivities.In automatic mode, the dielectric loss tangents and the volume resistivities are automatically measured, and then the results are printed out with the built-in printer. And the relative permittivities and the volume resistivities calculated are also printed out. Therefore the test time is greatly saved compared to the conventional test methods.

  • Current Transformer Testers

    Vanguard Instruments Company, Inc.

    Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface

  • High Voltage Apparatus Tester

    M4100 - Doble Engineering

    The M4100 is the industry standard for power apparatus and insulation testing. Its unique combination of test capabilities and artificial intelligence analysis software makes it the power industry's most trusted Power Factor/Tan-Delta instrument.The M4100 instruments are used around the globe thanks to their comprehensive testing options, safety features and measurement accuracy.

  • Solid Insulation Material Dielectric Loss and Constant Measuring Electrode

    Shanghai Launch Electric Co., Ltd.

    The electrode is used in dielectric constant εr and dielectric loss tgδ test for solid electrical material such as insulation paint, resin, rubber, fibrillated product, laminate, mica product, plastic, cable, film composite, porcelain and glass. The electrode is designed to use under power frequency of 50Hz, and comply with international standard GB1409-78.

  • Digital Insulation Multimeter Tester 1 KV

    MIRT-61 - The Motwane Manufacturing Company

    The MOTWANE multipurpose tester Model MIRT-61 is a Versatile, battery operated Digital insulation tester with true RMS industrial grade multimeter features best suited for industrial preventive maintenance. With test voltage range up to 1 KV , highest insulation resistance range of 6G Ohm and multi featured function of RMS multimeter (i.e. AC/DC 1000 V) ; makes it a superior offering for Industry and Service segment. It is designed predominantly for low voltage insulation resistance testing in maintenance and services, which involves the applications like Cables/Wires, Rotating Machines, LT transformers, Switchgears and Industrial installations. It is designed to suit the extreme environment conditions. Save your operating cost and test more with this single box design rather buying two different products.

  • PE/ Ground, Insulation Resistance Tester

    Handheld - Schleich Gmbh

    The safety testers of the Handheld class are used to measure PE/ Ground resistances, insulation resistances and to perform a simple functional test. The small and sturdy universal testers are intended for standard-compliant safety tests in workshops and production as well as for mobile operation during repair, installation, service and more.